I have seen this on a few macs, It look like the system starts a periodic offline SMART test and then aborts it before it has had time to complete!

#################################### START ####################################

smartctl version 5.36i [i686-apple-darwin8.7.1] Copyright (C) 2002-6 Bruce Allen

Home page is
http://smartmontools.sourceforge.net/

=== START OF INFORMATION SECTION ===

Device Model: FUJITSU MHV2120BHPL

Serial Number: NW81T64256LM

Firmware Version: 0081702E

User Capacity: 120,034,123,776 bytes

Device is: Not in smartctl database [for details use: -P showall]

ATA Version is: 7

ATA Standard is: ATA/ATAPI-7 T13 1532D revision 4a

Local Time is: Fri Sep 18 17:01:59 2009 CST

SMART support is: Available - device has SMART capability.

SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===

SMART overall-health self-assessment test result: PASSED

General SMART Values:

Offline data collection status: (0x00) Offline data collection activity

was never started.

Auto Offline Data Collection: Disabled.

Self-test execution status: ( 249) Self-test routine in progress...

90% of test remaining.

Total time to complete Offline

data collection: ( 702) seconds.

Offline data collection

capabilities: (0x7b) SMART execute Offline immediate.

Auto Offline data collection on/off support.

Suspend Offline collection upon new

command.

Offline surface scan supported.

Self-test supported.

Conveyance Self-test supported.

Selective Self-test supported.

SMART capabilities: (0x0003) Saves SMART data before entering

power-saving mode.

Supports SMART auto save timer.

Error logging capability: (0x01) Error logging supported.

General Purpose Logging supported.

Short self-test routine

recommended polling time: ( 2) minutes.

Extended self-test routine

recommended polling time: ( 82) minutes.

Conveyance self-test routine

recommended polling time: ( 2) minutes.

SMART Attributes Data Structure revision number: 16

Vendor Specific SMART Attributes with Thresholds:

ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

1 Raw
Read_ErrorRate 0x000f 100 100 046 Pre-fail Always - 99359

2 Throughput_Performance 0x0005 100 100 030 Pre-fail Offline - 32047104

3 Spin
UpTime 0x0003 100 100 025 Pre-fail Always - 1

4 Start
StopCount 0x0032 098 098 000 Old_age Always - 7122

5 Reallocated
SectorCt 0x0033 100 100 024 Pre-fail Always - 8589934592000

7 Seek
ErrorRate 0x000f 100 100 047 Pre-fail Always - 1600

8 Seek
TimePerformance 0x0005 100 100 019 Pre-fail Offline - 0

9 Power
OnHours 0x0032 089 089 000 Old_age Always - 20845863

10 Spin
RetryCount 0x0013 100 100 020 Pre-fail Always - 0

12 Power
CycleCount 0x0032 100 100 000 Old_age Always - 2154

192 Power-Off
RetractCount 0x0032 100 100 000 Old_age Always - 21

193 Load
CycleCount 0x0032 087 087 000 Old_age Always - 268796

194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 44 (Lifetime Min/Max 8/49)

195 Hardware
ECCRecovered 0x001a 100 100 000 Old_age Always - 2685

196 Reallocated
EventCount 0x0032 100 100 000 Old_age Always - 414187520

197 Current
PendingSector 0x0012 100 100 000 Old_age Always - 0

198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 1

199 UDMA
CRC_ErrorCount 0x003e 200 200 000 Old_age Always - 0

200 Multi
Zone_ErrorRate 0x000f 100 100 060 Pre-fail Always - 9016

203 Run
OutCancel 0x0002 100 100 000 Old_age Always - 2628568809206

240 Head
FlyingHours 0x003e 200 200 000 Old_age Always - 0

SMART Self-test log structure revision number 1

Num Test_Description Status Remaining LifeTime(hours) LBA
of_firsterror

# 1 Short offline Aborted by host 90% 5790 -

# 2 Short offline Aborted by host 90% 5790 -

# 3 Short offline Aborted by host 90% 5790 -

# 4 Short offline Aborted by host 90% 5790 -

# 5 Short offline Aborted by host 90% 5790 -

# 6 Short offline Aborted by host 90% 5790 -

# 7 Short offline Aborted by host 90% 5789 -

# 8 Short offline Aborted by host 90% 5789 -

# 9 Short offline Aborted by host 90% 5789 -

#10 Short offline Aborted by host 90% 5789 -

#11 Short offline Aborted by host 90% 5789 -

#12 Short offline Aborted by host 90% 5789 -

#13 Short offline Aborted by host 90% 5789 -

#14 Short offline Aborted by host 90% 5789 -

#15 Short offline Aborted by host 90% 5789 -

#16 Short offline Aborted by host 90% 5789 -

#17 Short offline Aborted by host 90% 5789 -

#18 Short offline Aborted by host 90% 5789 -

#19 Short offline Aborted by host 90% 5788 -

#20 Short offline Aborted by host 90% 5788 -

#21 Short offline Aborted by host 90% 5788 -

##################################### END #####################################

2 replies

Sign in or join Beachball Help to reply.

  1. 0

    Q Lazarus

    Imported from the Apple Support Forums via the Wayback Machine 🔗

    What it looks like to me is that you're using third party software to look at a lot of vendor-specific information that the drive stores on its own, and--like most drive vendors--this one's SMART implementation is not particularly useful for anything other than marketing.

    If you really care about this then I'd suggest leaving the computer alone, never letting the drive go to sleep, for a good long while and see if that allows the device to complete its self diagnostic.

  2. 0

    LittleSaint

    Imported from the Apple Support Forums via the Wayback Machine 🔗

    The best way to use SMART diagnostics with consumer drives is to keep your backups current and when the drive fails without warning, you're OK. If you see a question mark on your screen, and hear repetitive clicking noises, that's a good indicator of drive failure.